@echo off
-IF NOT EXIST "%VS100COMNTOOLS%..\..\VC\vcvarsall.bat" GOTO ERROR1
-
@REM Load local settings from file localenv.bat that should be located in the root directory
if "%ROOT_DIR%" == "" (
set ROOT_DIR=%~dp0..
set SALOME_ROOT_DIR=%ROOT_DIR%\SALOME
)
-if "%SOLVESPACE_ROOT_DIR%" == "" (
- SET SOLVESPACE_ROOT_DIR=%ROOT_DIR%\products\solvespace-2.0
+if "%PLANEGCS_ROOT_DIR%" == "" (
+ SET PLANEGCS_ROOT_DIR=%SALOME_ROOT_DIR%\PRODUCTS%OCC_LIB_PREFIX%\planegcs-0.18
+)
+SET PATH=%PLANEGCS_ROOT_DIR%\lib;%PATH%
+
+if "%EIGEN_ROOT_DIR%" == "" (
+ SET EIGEN_ROOT_DIR=%SALOME_ROOT_DIR%\PRODUCTS%OCC_LIB_PREFIX%\eigen-3.2.7
)
-SET PATH=%SOLVESPACE_ROOT_DIR%\lib;%PATH%
-cd %SALOME_ROOT_DIR%\WORK
+if "%BOOST_ROOT_DIR%" == "" (
+ if "SALOME_ROOT_DIR" == "" (
+ SET BOOST_ROOT_DIR=%ROOT_DIR%\products\boost-1.67.0
+ ) else (
+ SET BOOST_ROOT_DIR=%SALOME_ROOT_DIR%\PRODUCTS%OCC_LIB_PREFIX%\boost-1.67.0
+ )
+)
+
+cd /d %SALOME_ROOT_DIR%\WORK
call set_env.bat %1
-call "%PDIR%\env_compile.bat"
-cd %ROOT_DIR%
+
+if "%2" == run (
+ call "%PDIR%\env_launch.bat"
+) else (
+ call "%PDIR%\env_compile.bat"
+)
+
+cd /d %ROOT_DIR%
@REM -------------------------
@REM Python
@REM -------------------------
@REM CASCADE
-@SET PATH=%CASROOT%;%CASROOT%\win32\bin%OCC_LIB_PREFIX%;%PATH%
-@SET LIB=%CASROOT%\win32\lib%OCC_LIB_PREFIX%;%LIB%
+@SET PATH=%CASROOT%;%CASROOT%\win64\vc14\bin%OCC_LIB_PREFIX%;%PATH%
+@SET LIB=%CASROOT%\win64\vc14\lib%OCC_LIB_PREFIX%;%LIB%
@set CSF_MDTVFontDirectory=%CASROOT%\src\FontMFT
@set CSF_LANGUAGE=us
@set MMGT_CLEAR=1
@SET PYTHON_INCLUDE=%PYTHONHOME%\include
@REM -------------------------
-
@REM -------------------------
@REM Some OCCT headers include FREETYPE headers
-@SET FREETYPE_ROOT_DIR=%PDIR%\freetype-2.4.11
+@SET FREETYPE_ROOT_DIR=%PDIR%\freetype-2.9.0
@REM -------------------------
@SET PATH=%GEOM_ROOT_DIR%\lib\salome;%PATH%
@SET _NO_DEBUG_HEAP=1
-IF "%ARCH%" == "Win64" (
- call "%VS100COMNTOOLS%..\..\VC\vcvarsall.bat" x64
-) ELSE (
- IF "%ARCH%" == "Win32" (
- call "%VS100COMNTOOLS%..\..\VC\vcvarsall.bat" x86
- ) ELSE (
- echo Wrong architecture is used. Win32 or Win64 architecture is allowed only.
- echo Refer to the set_env.bat script.
- )
+@SET VC_VERSION_SHORT=15
+for /f "tokens=1,2*" %%a in ('reg query "HKLM\SOFTWARE\Wow6432Node\Microsoft\VisualStudio\SxS\VS7" /v "%VC_VERSION_SHORT%.0" 2^>nul') do set "VSPATH=%%c"
+IF NOT EXIST "%VSPATH%\VC\Auxiliary\Build\vcvarsall.bat" GOTO ERROR1
+
+if exist "%VSPATH%\Common7\IDE\devenv.exe" (
+ SET msvc_exe=devenv
+) else if exist "%VSPATH%\Common7\IDE\VCExpress.exe" (
+ SET msvc_exe=VCExpress
+) else (
+ GOTO ERROR1
)
+call "%VSPATH%\VC\Auxiliary\Build\vcvarsall.bat" x64 > NUL
+
+@SET SHAPER_ROOT_DIR=%ROOT_DIR%\install
+@SET PATH=%SHAPER_ROOT_DIR%\lib\salome;%PATH%
+REM @SET PYTHONPATH=%SHAPER_ROOT_DIR%\lib\python2.7\site-packages\salome\salome;%PYTHONPATH%
+REM @SET PYTHONPATH=%SHAPER_ROOT_DIR%\bin\salome;%PYTHONPATH%
+
+@SET LightAppConfig=%SHAPER_ROOT_DIR%\share\salome\resources\shaper;%GUI_ROOT_DIR%\share\salome\resources\gui
+
+goto END
-@SET NEW_GEOM_CONFIG_FILE=%ROOT_DIR%\install\plugins
-@SET NEWGEOM_ROOT_DIR=%ROOT_DIR%\install
-@SET PATH=%NEWGEOM_ROOT_DIR%\swig;%NEWGEOM_ROOT_DIR%\plugins;%NEWGEOM_ROOT_DIR%\bin;%PATH%
-@SET PYTHONPATH=%NEWGEOM_ROOT_DIR%\swig;%NEWGEOM_ROOT_DIR%\plugins;%NEWGEOM_ROOT_DIR%\addons;%NEWGEOM_ROOT_DIR%\pythonAPI;%PYTHONPATH%
+:ERROR1
+ECHO "Visual Studio environment file is not found."
-@SET LightAppConfig=%%NEWGEOM_ROOT_DIR%\share\salome\resources\newgeom;%GUI_ROOT_DIR%\share\salome\resources\gui
-@SET NewGeomResources=%NEWGEOM_ROOT_DIR%\resources
+:END