1 # MODIF DATE 24/10/2006 AUTEUR DURAND C.DURAND
2 # CONFIGURATION MANAGEMENT OF EDF VERSION
3 # ======================================================================
4 # COPYRIGHT (C) 1991 - 2001 EDF R&D WWW.CODE-ASTER.ORG
5 # THIS PROGRAM IS FREE SOFTWARE; YOU CAN REDISTRIBUTE IT AND/OR MODIFY
6 # IT UNDER THE TERMS OF THE GNU GENERAL PUBLIC LICENSE AS PUBLISHED BY
7 # THE FREE SOFTWARE FOUNDATION; EITHER VERSION 2 OF THE LICENSE, OR
8 # (AT YOUR OPTION) ANY LATER VERSION.
10 # THIS PROGRAM IS DISTRIBUTED IN THE HOPE THAT IT WILL BE USEFUL, BUT
11 # WITHOUT ANY WARRANTY; WITHOUT EVEN THE IMPLIED WARRANTY OF
12 # MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SEE THE GNU
13 # GENERAL PUBLIC LICENSE FOR MORE DETAILS.
15 # YOU SHOULD HAVE RECEIVED A COPY OF THE GNU GENERAL PUBLIC LICENSE
16 # ALONG WITH THIS PROGRAM; IF NOT, WRITE TO EDF R&D CODE_ASTER,
17 # 1 AVENUE DU GENERAL DE GAULLE, 92141 CLAMART CEDEX, FRANCE.
18 # ======================================================================
19 #------------------------------------------------------
20 # LAMBDA EN FONCTION DE LA TEMPéRATURE
48 # RHO_CP EN FONCTION DE LA TEMPéRATURE
76 # E EN FONCTION DE LA TEMPéRATURE
87 100. ,191.5E+9 *coef2,
88 150. ,187.5E+9 *coef2,
89 200. ,184.0E+9 *coef2,
90 250. ,180.0E+9 *coef2,
91 300. ,176.5E+9 *coef2,
92 350. ,172.0E+9 *coef2,
93 400. ,168.0E+9 *coef2,
94 450. ,164.0E+9 *coef2,
95 500. ,160.0E+9 *coef2,
96 550. ,155.5E+9 *coef2,
97 600. ,151.5E+9 *coef2,
101 # NU EN FONCTION DE LA TEMPéRATURE
106 PROL_DROITE='CONSTANT',
107 PROL_GAUCHE='CONSTANT',
112 # ALPHA EN FONCTION DE LA TEMPéRATURE
119 VALE=( 20., 15.54E-6, 50., 15.72E-6,
120 100., 16.00E-6, 150., 16.30E-6,
121 200., 16.60E-6, 250., 16.86E-6,
122 300., 17.10E-6, 350., 17.36E-6,
123 400., 17.60E-6, 450., 17.82E-6,
127 # COURBE DE FATIGUE DE WOHLER RCCM Z1.4.2
129 _AZ=DEFI_FONCTION(NOM_PARA='SIGM',
149 _BZ=CALC_FONCTION(INVERSE=_F(FONCTION=_AZ,),);
150 _CZ=CALC_FONCTION(COMB=_F(FONCTION = _BZ,
151 COEF = 1.E ## UNIT -6
153 DETRUIRE( CONCEPT =_F( NOM=_AZ), )
154 _AZ=CALC_FONCTION(INVERSE=_F(FONCTION=_CZ,),);
160 THER_NL=_F( ## SUBST THER
161 RHO_CP = _A1, ## EVAL _A1
162 LAMBDA = _A0, ## EVAL _A0
164 ELAS_FO=_F( ## SUBST ELAS
166 NU = _A3, ## EVAL _A3
167 ALPHA = _A4, ## EVAL _A4
168 TEMP_DEF_ALPHA = 20., ## SUPPR
171 FATIGUE=_F(WOHLER=_AZ,
172 E_REFE=1.79E11*1.E ## UNIT -6